Isolation transformers
Isolation Transformers have primary and secondary windings that are physically separated from each other. The windings of isolation transformer sare insulated from each other and are referred to as "insulated". In an isolation transformer the output winding will be isolated. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment.
An isolation transformer allows an AC signal or power to be taken from one device and fed into another without electrically connecting the two circuits. Isolation transformers block transmission of DC signals from one circuit to the other, but allow AC signals to pass. They also block interference caused by ground loops. Isolation transformers are different from auto transformers in which the primary and secondary share a common winding. Isolation transformers are often used to protect high gain circuits, or prevent noisy ground paths in instrumentation.
Distribution TransformersDistribution transformers convert high-voltage electricity to lower voltage levels acceptable for use in homes and business. Function of a distribution transformer is to step down the voltage and provide isolation between primary and secondary. Electrical energy is passed through distribution transformers to reduce high-distribution voltage levels down to end-use levels.Please choose Three phase or Single phase transformers from our the menu. 3 phase isolation transformers have 3 primary and 3 secondary windings that are physically separated from each other. Sometimes these isolation transformers are referred to as "insulated". This is because the windings are insulated from each other.In a 3 phase isolation transformer the output windings will be isolated, or floating from earth ground unless bonded at the time of installation. Copper and aluminum are used for transformer windings. These materials are available in a variety of grades and thickness, each with their own efficiency characteristic. Winding losses, or load losses, arise from the conducting material's inherent resistance to the flow of electrical current. Winding losses increase with the square of the transformer load. Efficiency gains can by achieved by using materials with lower resistively or greater diameter. For example, coils make with copper can have considerably lower load losses than those make with other materials. Data based on popular 45 kVA size shows $1000/ year savings. That is $10,000 saved over ten years. |
Toll free: 1-888-500-2417 Mon-Fri: 9am-4pm. EST.
Your IP Address is: 38.107.179.231
Your IP Address is: 38.107.179.231
Copyright © 2012 Canada Transformers